CCA: 240A
Dimensions: 110 (L) x 55 (W) x 75 (H) mm
Weight: 740g

€91.20 Tax included

€76.00 Tax excluded

PAIEMENT SÉCURISÉ
LIVRAISON EXPRESS
CONTACTEZ-NOUS

Solise 12V CCA-240 Lithium Starter Battery - Connection Kit Included.

The Solise 12V CCA-240 Lithium Starter Battery easily replaces lead-acid, gel or AGM batteries. No modifications are required, provided the battery is compatible with the vehicle. Thanks to Lithium Iron Phosphate (LiFePO4) technology, it offers a longer service life, reduced weight and excellent reliability. Discover lithium battery technology.

Our Black Power lithium battery range has been designed to provide a high-performance, ultra-compact and lightweight solution. These batteries require no active maintenance. Thanks to the detachable connector system, you can use a single battery across several compatible vehicles. This battery is ideal for applications requiring a reliable and long-lasting 12V power supply.

The Solise 12V CCA-240 Lithium Starter Battery is particularly suitable for applications requiring high starting current. It delivers 240A for 10 seconds. It can also power 12V electrical equipment, provided the continuous discharge current does not exceed 140A.

We recommend adding the balancing board (ACC009) if you do not purchase the protective case. Also discover our range of Solise lithium motorcycle batteries.

Thanks to their low self-discharge rate (<3% per month), lithium batteries can be stored for extended periods under suitable conditions. Charge loss remains minimal. Unlike lead-acid or AGM batteries, no regular maintenance is required. The Solise 12V CCA-240 Lithium Starter Battery offers a modern and long-lasting solution. It effectively replaces conventional batteries in compatible motorcycles and vehicles.

TECHNICAL SPECIFICATIONS

Voltage: 12V
Capacity: 5Ah
Charging voltage: 13.8V to 14.4V
Starting current: 240A for 10 seconds
Fast charging current: 20A for 15 minutes
Continuous discharge current: 140A
Self-discharge: <3% per month
Operating temperature: -20°C to 60°C
Charging temperature: 0°C to 45°C
Cycle life: 2,000 cycles at 1C and 100% DOD
Dimensions: 110 (L) x 55 (W) x 75 (H) mm
Weight: 740g

Ingress Protection Rating: IP40 - No protection against water ingress.

The battery is enclosed in a flexible heat-shrink plastic sleeve. Make sure that neither the battery nor its connectors come into contact with any metal parts of the motorcycle. Ensure that the entire battery installation is properly insulated and protected from the motorcycle's metal components. Do not expose the battery to water, flames or heat sources exceeding 60°C. Do not charge at a voltage higher than 14.6V.

This battery does not include a BMS (Battery Management System).

INCLUDED CONNECTION KIT

- One Anderson 50A connector cable (compatible with the motorcycle's electrical connections) with two 6mm ring terminals at the other end
- 2 M6 screws for securing the washers and nuts
- 2 heat-shrink tubes for insulation

Cable length: 170mm
Maximum continuous cable current: 50A
Maximum cable current for 10 seconds: 550A

STANDARDS

Certifications: RoHS | CE | UN38.3

Warranty: 1 year

Solise
BM12005

RECOMMENDATIONS FOR USING LITHIUM SOLISE BATTERIES

To ensure optimal, safe performance and long life for your SOLISE lithium batteries, we recommend that you follow these guidelines :

USE AND RECHARGING 

  • Suitable charger : Use a charger specifically designed for lithium batteries to optimize recharging.
  • Disconnection : Disconnect your battery if you are not going to use it for more than 2 weeks, to avoid deep discharge.
  • Prolonged inactivity : If you've never used your battery after purchasing it, you'll need to recharge it after 18 months.
  • Quality connection : Make sure the battery connection is of good quality to avoid any operating problems.

STORAGE 

  • Wintering : If you're using your battery and want to store it for the winter, you'll need to fully recharge it. You can then store it for up to 18 months without risk.

PROTECTION AND SAFETY 

  • Exposure to water : Protect the battery from splashing water and damp environments to avoid the risk of short-circuiting and corrosion.
  • Short circuit : Do not short-circuit, as this may cause irreversible damage and a fire hazard.
  • Exposure to flames : Do not expose the battery to flames. 
  • Protective casing : Do not remove the plastic protective casing, which provides electrical insulation and mechanical protection.

CHARGING CONDITION

  • Temperature : Do not recharge the battery at temperatures below 0°C or above 60°C. To prevent overheating, avoid placing the battery too close to the engine.
  • Recharging voltage : Your alternator must not recharge the battery at a voltage higher than 14.6V.
  • Discharging : Do not discharge the battery below 9V.

These batteries have no protection against overcharge, deep discharge or short-circuit.

We strongly recommend the addition of our balancing card (part no. ACC009), which balances the cells during charging, thus extending battery life. Once installed, the balancing board must not be disconnected. 

THE CONSEQUENCES OF MISUSE

  • Loss of technical characteristics : If these recommendations are not followed, the battery may lose its technical characteristics irreversibly and will not be covered by warranty.
  • Fire hazard : If misused, the battery can catch fire.

RECYCLING USED BATTERIES

These products must not be thrown away. SOLISE works with the Screlec organisation to take care of used batteries. You can return them to your local waste collection centre for proper recycling.